TM9Y - Flashing Code 8

York Gas Furnace: TM9T/TM9Y

Re: No Heat - Flashing Code 8

Code 8 = Flame was established but later lost - 5 times.

► This is a Soft-Lockout which will automatically reset after 1 hour.

Qty Possible Causes:
4 Dirty Flame Sensor
1 Water in Inducer
Clogged Burners
No or Low Gas Pressure
Bad Gas Valve
Combustion Air Problem
Water in the Gas Line


CHECKOUT:

1. Check Ignition Sequence


2. Check Ignition


3. Check Gas Pressure / Valve


4. Check Flame Sensor


5. Monitor Burners



Article ID: 577
Last updated: 28 Mar, 2023
Revision: 7
Equipment -> Gas Furnaces -> York -> TM9Y -> TM9Y - Flashing Code 8
https://ghac.makekb.com/entry/577/