GMNT - Flashing Code 3

Goodman Gas Furnace: GMNT

Re: Flashing Code 3

If, after the vent blower is energized, the pressure switch does not close, the control will keep the blower on and wait for the switch to close. The diagnostic code for this problem is 3 short flashes followed by a pause.

► The diagnostic code will go away once the pressure switch closes.


Qty Possible Causes:
2 Bad Inducer Motor
Bad Pressure Switch
Water in the vent (improper slope)
Water in inducer (clogged drain)
1 Clogged / Frozen Drain
Item Stuck in Inducer Motor
Bad Ignition Control


CHECKOUT:

1. Check Control Board


2. Check Inducer Motor


3. Check Pressure Switch


4. Check Condensate Drainage



Article ID: 541
Last updated: 1 Feb, 2019
Revision: 3
Equipment -> Gas Furnaces -> Goodman -> GMNT -> GMNT - Flashing Code 3