P3UR - Flashing Code 3

York 90% Gas Furnace: P3UR

Re: Flashing Code 3

Code 3 = Furnace Pressure Switch failed to close on a call for heat.


Qty Possible Causes:
2 Bad Inducer Motor
1 Bad Pressure Switch
1 Clogged / Frozen Drain
1 Pressure Hose Problem
2 Item Stuck in Inducer Motor
Water in the vent (improper slope)
Water in inducer (clogged drain)
Restricted Intake
Bad Ignition Control


CHECKOUT:

1. Check Control Board


2. Check Inducer


3. Check Pressure Switch


4. Check Condensate Drainage



Article ID: 516
Last updated: 17 Mar, 2021
Revision: 17
Equipment -> Gas Furnaces -> York -> P3UR / P3DH -> P3UR - Flashing Code 3