York Gas Furnaces: PMPD
Re: Diagnostic/Lockout Codes
This York gas furnaces has a control board inside the furnace blower compartment that will flash a diagnostic code that shows the operating status of the furnace.
| Diagnostic Codes: | ||
| Steady On Red | Control failure |
|
| 1 Red | Ignition Lockout |
|
| 2 Red | Pressure switch stuck closed |
|
| 3 Red | Pressure switch stuck open |
|
| 4 Red | Limit switch open |
|
| 5 Red | Rollout switch open |
|