ERD - Defrost Problem/Outdoor Coil Frozen

York Heat Pump: ERD

Re: Not Defrosting / Frozen

The ERD models use a Demand Defrost control board.

The board uses an Ambient (outdoor) Sensor and Liquid Line Sensor to determine the proper conditions for defrost to occur.


Qty Possible Causes:
1 Bad Liquid Line Sensor
  Bad Condenser Fan Motor
Bad Fan Capacitor
  Bad Defrost Board
Low Refrigerant Charge
Bad Expansion Valve


CHECKOUT:

1. Check Outdoor Fan


2. Test Defrost Cycle


3. Check Refrigerant Pressures

Normal Pressure Range
Refrigerant 0-30 Deg O/D 30-50 Deg O/D
R-22
  • 20-35 Suction
  • 160-220 Discharge
  • 36-65 Suction
  • 170-260 Discharge

4. Check Liquid Line Sensor


5. Check Ambient Sensor