TM9T - Flashing Code 4

York Gas Furnace: TM9T

Re: Flashing Code 4

Code 4 = Main limit switch has opened its normally closed contacts.

 If the limit switch has not closed within five minutes, the control will assume that the blower is not functioning, will start a hard lockout and will begin to flash the 11 Red Flashes error code. Power will have to be cycled off and on to reset the control after the problem has been corrected. See “Flashing Code 11”

► If the main limit switch opens five times within a single call for heat, the control will also indicate 4 Red Flashes and will enter a one-hour soft lockout.


Qty Possible Causes (From Most to Least Likely):
Dirty Air Filter
Clogged Evaporator Coil
High Duct Static
1 High Gas Pressure
Bad Limit
1 Blower Speed too Low


CHECKOUT:

1. Check Temperature Rise


2. Check Air Filter


3. Check Gas Pressure


4. Check Blower Speed


5. Check Duct Static Pressure