YZF - High Pressure Fault (Heating)

York Heat Pump: YZF

Re: High Pressure Fault (Heating)

The heat pump was running in normal heat mode (not in defrost) and the high pressure switch tripped.

High Pressure Lockout is indicated by the following LED pattern on the outdoor unit control board:


X/L Output


Qty Possible Causes:
1 Bad Blower Motor
2 Refrigerant Over-Charge
1 Stuck Compressor Contactor
Bad O/D Expansion Valve
Low Indoor Airflow
Refrigerant Restriction
Bad Pressure Switch


CHECKOUT:

1. Check Compressor Contactor


2. Check Indoor Airflow


3. Check Blower Motor


4. Check Refrigerant Pressures

Normal Pressure Range
Refrigerant 0-30 Deg O/D 30-50 Deg O/D
R410A
  • 75-100 Suction
  • 250-320 Discharge
  • 100-150 Suction
  • 250-375 Discharge

5. Check Sub-Cooling


6. Check Indoor Airflow


7. Check Duct Static Pressure



Article ID: 443
Last updated: 25 Feb, 2021
Revision: 5
Equipment -> Heat Pumps -> York -> YZB / YZF -> YZF - High Pressure Fault (Heating)