2TWR3 - Defrost Problem/Outdoor Coil Frozen

Trane Heat Pump: 2TWR3

Re: Not Defrosting / Frozen

This model uses a Demand Defrost control board.

The board uses an Ambient (outdoor) Sensor and Liquid Line Sensor to determine the proper conditions for defrost to occur.


Qty Possible Causes:
Bad Liquid Line Sensor
Bad Condenser Fan Motor
Bad Fan Capacitor
Bad Defrost Board
Low Refrigerant Charge
Bad Expansion Valve
1 No 24VAC Power


CHECKOUT:

1. Check Outdoor Fan


2. Test Defrost Cycle


3. Check Refrigerant Pressures

Normal Pressure Range
Refrigerant 0-30 Deg O/D 30-50 Deg O/D
R-22
  • 20-50 Suction
  • 150-250 Discharge
  • 55-70 Suction
  • 175-275 Discharge

4. Check Liquid Line Sensor


5. Check Ambient Sensor


6. Defrost Termination Temperature