YHJF - Defrost Problem/Outdoor Coil Frozen

York Heat Pump: YHJF24 - 48

Re: Not Defrosting / Frozen

The YHJF 2 to 4 Ton models use a Demand Defrost control board (the 5 Ton model uses a Yorkguard VI)

The board uses an Ambient (outdoor) Sensor and Liquid Line Sensor to determine the proper conditions for defrost to occur.


Qty Possible Causes:
14 Bad Liquid Line Sensor
3 Bad Defrost Board
3 Bad Condenser Fan Motor
Mis-Placed Coil Sensor
Bad Fan Capacitor
Low Refrigerant Charge
Bad Expansion Valve
1 Stuck Contactor


CHECKOUT:

1. Check Contactor 


2. Check Outdoor Fan


3. Test Defrost Cycle


4. Check Refrigerant Pressures

DEFROST MODE

Defrost Termination
Refrigerant Suction Pressure Discharge Pressure Liquid Line Temperature
R410A

100-120 Suction

300-375 Discharge

80-90 Deg

HEATING MODE

Normal Pressure Range
Refrigerant 0-30 Deg O/D 30-50 Deg O/D
R410A
  • 75-100 Suction
  • 250-320 Discharge
  • 100-150 Suction
  • 250-375 Discharge

5. Check Liquid Line Sensor


6. Check Ambient Sensor



Article ID: 428
Last updated: 19 Jan, 2021
Revision: 34
Equipment -> Heat Pumps -> York -> YHJD/YHJF -> Heating -> YHJF - Defrost Problem/Outdoor Coil Frozen