PCC/PUC - No Heat / Won't Come On

York Gas Furnaces: PCC/PUC

Re: Furnace Won't Come On / No Heat

This condition is generally reported two different ways by the customer:

  1. "The furnace won't do anything." - Indicating that there is no activity from the furnace on a call for heat.
  2. "The furnace makes a noise, but it never blows-out hot air." - Indicating that the inducer motor runs, but ignition never takes place.

These furnaces use either a Robertshaw SP735 or White-Rodgers 50E47 hot-surface ignition controller.

Diagnostic Light:


Qty Possible Causes (From Most to Least Likely):
2 Bad Glow Plug
1 Auxiliary Limit Tripped
Pressure Switch Fault
No Power (Door Switch)
Ignition Control Locked-Out
Bad Inducer Fan
Bad Ignition Control
Bad Thermostat (Thermostat not calling)


CHECKOUT:

1. Check Power


2. Check Safeties


3. Check Ignition Control


4. Check Glow Plug



Article ID: 397