P3DH - Flashing Code 4

York Gas Furnace: P3DH

Re: Flashing Code 4

CODE 4 = High Limit or Blower Limit Open

There are three limits on this furnace:

If any of the three limit controls open, the burners will be de-energized and the air circulation and vent blower will be turned on until the limit closes. The diagnostic light code for this is four short flashes followed by a pause.

► The diagnostic code will go away once the limit switch closes.


Qty Possible Causes:
Dirty Air Filter
1 Clogged Evaporator Coil
Under-sized Ductwork
High Gas Pressure
Bad Limit
Bad Blower Motor
Blower Speed too Low
Blocked Vent (Spill Limit)
Power Loss During Heat Cycle


CHECKOUT:

1. Check Limit Circuit


2. Check Heating Operation


3. Check Blower Motor/Capacitor


4. Check Temperature Rise


5. Check Duct Static Pressure