TUX1/TDX1 - Flashing Code 3

Gas Furnace: TUX1/TDX1

Re: Flashing Code 3

Code 3 = Pressure switch fault

A Code 3 will result from either of the following conditions:

► If the pressure switch is in the "Closed" position when a call for heat is initiated, the control board will flash a Code 3 and NOT power the inducer motor.


Qty Possible Causes:
2 Bad Inducer Motor / Capacitor
2 Clogged Drain
2 Bad Pressure Switch
1 Bad Control Board
Vent Pipe Problem
Intake Pipe Problem
ADPS Switch Set Too Low


CHECKOUT:

1. Check Sequence


2. Check Inducer Motor


3. Check Pressure Switch


4. Check Condensate Drain


5. ADPS Switch Setting