P1XU - Flashing Code 6

York Gas Furnace: P1XU

Re: Flashing Code 6

The P1XUD gas furnace has a 2-stage gas valve and 2-speed inducer fan motor. There are two, dual-port pressure switches which monitor both low and high speed operation of the inducer motor.

The low pressure port of the switches goes to the inducer motor and the high pressure goes to the burner compartment.

Code 6 = Pressure switch opened 4 times during a run cycle.

► This is a "Soft Lockout" which will automatically reset after 1 hour.


Qty Possible Causes (From Most to Least Likely):
Bad Inducer Motor
Restricted Vent
Restricted Intake
Water in Inducer
Clogged Drain
Bad Pressure Switch
Water in Pressure Switch / Tubing


CHECKOUT:

1. Check Inducer Motor Operation


2. Check Pressure Switch


3. Check Condensate Drainage




Article ID: 379
Last updated: 30 Oct, 2017
Revision: 7
Equipment -> Gas Furnaces -> York -> P1XU -> P1XU - Flashing Code 6