York Gas Furnaces
Re: Lockout Codes
Most York gas furnaces have a control board inside the furnace blower compartment that will flash a diagnostic code that shows the operating status of the furnace.
Diagnostic Codes: | ||
Slow Green | Normal Operation - no call for heat | |
Slow Amber | Normal Operation - with a call for heat | |
Steady On Red | Control failure |
|
Rapid Red | Twinning error, incorrect 24V phasing |
|
Rapid Amber | Low flame sense current |
|
4 Amber | Y present without G |
|
1 Red | Flame present with gas off |
|
2 Red | Pressure switch stuck closed |
|
3 Red | Pressure switch stuck open |
|
4 Red | Limit switch open / open fuse |
|
5 Red | Rollout switch open / open fuse |
|
6 Red | Pressure switch opened 4 times |
|
7 Red | Ignition lockout due to 3 retries |
|
8 Red | Flame signal lost 5 times |
|
9 Red | Grounding or line polarity fault |
|
10 Red | Flame sensed with no call for heat |
|
11 Red | Extended limit switch open |
|
12 Red | Open igniter circuit |
|
13 Red | 2nd Stage Pressure switch stuck open |
|
Fault Code Retrieval: With no thermostat call push and release the LAST ERROR button. The LED will flash up to 5 stored fault codes, beginning with the most recent. If there are no codes in memory, the LED will flash two green flashes.
Clear the Fault Codes: Push and hold the LAST ERROR button for at least five seconds. The LED will flash three green flashes when the memory has been cleared.