Heat Pump - Flashing Code 2 (Heating)

York Heat Pump: Yorkguard IV & Yorkguard V

Re: Flashing Code 2 (Heating)

Code 2 = High Discharge Pressure

If the Hi Pressure circuit input on the Yorkguard opens, the module will go into a Code 2 lockout and disable compressor operation.


Qty Possible Causes (Heating):
1 Bad Capacitor
Bad Blower Motor
1 Refrigerant Overcharge
Bad O/D Expansion Valve
Bad Fan Relay/Control
Bad Pressure Switch
Clogged Filter
Dirty Indoor Coil


CHECKOUT:

1. Check Operation


2. Check Blower Motor & Capacitor


3. Check Refrigerant Pressures

Normal Pressure Range
Refrigerant 0-30 Deg O/D 30-50 Deg O/D
R-22
  • 20-40 Suction
  • 150-225 Discharge
  • 40-75 Suction
  • 170-260 Discharge
R410A
  • 75-100 Suction
  • 250-320 Discharge
  • 100-150 Suction
  • 250-375 Discharge

4. Check Air Temperature Rise



Article ID: 254
Last updated: 6 Feb, 2023
Revision: 19
Equipment -> Heat Pumps -> York -> EFH -> Heat Pump - Flashing Code 2 (Heating)