58MXA - Flashing Code 33/Fault Code 33

Carrier Gas Furnaces: 58MXA

Re: Flashing Code 33 / Fault Code 33

Diagnostic Light Sequence: 3-Short Flashes, 3-Long Flashes (- - - , — — —)

On Carrier 58 Series Furnaces, the Primary Limit is wired in series with other limits, including up to two Rollout Switches or a Fusible-Link rollout switch.

Therefore, a Fault Code 33 can be caused by one of the following:

► If the limit circuit stays open for more than 3 minutes, the code changes to Code 13.


Qty Possible Causes:
Dirty Filter
Clogged Evaporator Coil
Restricted Ductwork
Bad Heat Exchanger
Bad Limit Switch
Excessive Gas Pressure
Bad Control Board

CHECKOUT:

1. Check Furnace Operation


2. Check Blower Motor


3. Check Temperature Rise


4. Check Air Filter


5. Check Gas Pressure


6. Check Duct Static Pressure


7. Check Limit Circuit



Article ID: 184
Last updated: 27 Oct, 2023
Revision: 28
Equipment -> Gas Furnaces -> Carrier/Bryant -> 58MXA -> 58MXA - Flashing Code 33/Fault Code 33