GUC/GUX - Flashing Code 1

Amana Gas Furnace; GUC/GUX

Re: Flashing Code 1

Light: The diagnostic light will indicate this condition with one short on flash followed by a longer off.

Reset: The control can be reset and brought out of lockout mode by turning the thermostat off and then back on.


Qty Possible Causes (From Most to Least Likely):
2 Bad Ignitor/Glow Plug
3 Dirty flame sensor
No Gas
Clogged Burners
Bad Gas Valve
1 Bad Ignition Control


CHECKOUT:

1. Check Glow Plug


2. Check Ignition


3. Check Gas Valve


4. Check Flame Sensor