Heil Gas Furnace - Won't Ignite

Heil Gas Furnace: NTGM, GNK, NCGM, GCK

Re: Burners Don't Ignite

These furnaces use a Honeywell Smart Valve for ignition control.


Qty Possible Causes:
Low Pilot Flame
Dirty Flame Sensor
1 Bad Smart Valve
1 Pressure Switch
Aux Limit Switch
Low Gas Pressure

CHECKOUT

1. Check Power


2. Check Smart Valve


3. Check Safeties

  1. Check Glow Plug
    • Inspect glow plug for any visible defects.
    • Remove flat 4-wire plug from the Smart Valve.
      • Check resistance of the glow plug across the two blue wires.
        • No resistance = Bad Glow Plug
    • Re-insert the flat 4-wire plug on the Smart Valve.
      • Check for 24VAC between the two blue wires on the plug.
        • No Voltage = Valve Locked-Out or Bad Smart Valve --> Cycle power to the furnace to reset possible lockouts then re-check.
  2. Check Pilot
    • If pilot gas is present and the glow plug glows, the pilot should light.
      • Glow plug glows but doesn't light pilot = No Gas, Clogged Pilot Orifice or Bad Smart Valve
    • Make sure the pilot flame makes good contact with the flame sensor.
      • Pilot lights by but never lights main gas = Dirty Flame Sensor or Clogged Pilot Orifice
        • In some cases, it is necessary to bend the pilot hood to better direct pilot flame to sensor.