Rheem - RPNL/RPQL Lockout / Fault Codes

Rheem Heat Pumps: RPNL/RPQL

Re: Lockout Codes

"L" Terminal Output
Flashes Description
1 Compressor running extremely long cycles
2 Low or High Pressure control trip
3 Unit short cycling
5 Compressor will not run
8 Control mis-operation
9 Low control voltage

7-Segment Display Codes
0 Standby No call for operation
c Call on Y1 1st Stage Unit Operation
C Call on Y2 2nd Stage Unit Operation
d Defrost Unit is in Defrost Mode
d (flash) Abnormal Defrost
F ICC Fuse Open Low voltage short
21 Low pressure trip (auto reset)
L21 Low Pressure Lockout (hard lockout)
23 High Pressure Trip (auto reset)
L23 High Pressure Lockout (hard lockout)
25 Bad OD Temperature Sensor Control will continue to operate
27 Abnormally Low Line Voltage
28 Abnormally High Line Voltage
L5 Compressor Lockout (hard lockout)

Hard Lockout Reset Methods:

  1. Removing Line Voltage
  2. Removing Low Voltage
  3. Pressing control TEST button for 1 second.

FAULT RECALL

To enter FAULT RECALL mode press both TEST and SW2 buttons at the same time with insulated probes for 1 second and release.


CLEAR FAULT HISTORY

To clear FAULT HISTORY press both TEST and SW2 buttons at the same time with insulated probes for 5 seconds and release.