Trane Heat Pump - Not Heating / Blowing Cold

Trane Heat Pump

Re: Compressor Won't Run / Compressor Can't Start

With a heat pump system, as long as the auxiliary heaters are working, the conditioned space should stay at or near the thermostat heating setpoint, but if the heat pump itself is not working the customer may report one or both of the following:


Checking the outdoor unit, it is found that the outdoor fan is on but the compressor is not running.

Other Symptoms:


Qty Possible Causes :
Bad Capacitor
Burnt Compressor Terminals
Locked-up Compressor
Bad Contactor
Low Voltage

CHECKOUT

1. Check Voltage


2. Check Capacitor


3. Check Terminals / Resistance


4. Add a "Hard Start"